§ 11-4. Air quality objectives.  


Latest version.
  • A. 
    Point of measurement shall be between six feet and 200 feet aboveground in the ambient air at any point within the City of Norwalk.
    B. 
    SO2 levels at point measurement shall not exceed the following limits: twenty-four-hour average, 0.05 ppm or 131 ug/M; one-hour average, 0.10 ppm or 262 ug/4. (25° C. SP)
    C. 
    Soiling index at point of measurement shall not exceed the following limits: twenty-four-hour average, 1.0 Coh/1,000 feet; two-hour average, 3.0 Coh/1,000 feet.
    (1) 
    Automatic smoke samplers which continuously produce a record of the time, duration and density or opacity of air contaminants shall be recommended equipment for all stacks connected to fuel- or refuse-burning installations rated at or greater than 10,000,000 BTU per hour.
    D. 
    Total suspended particulates at point of measurement shall not exceed the following limits: twenty-four-hour maximum, 200 ug/M; weekly average, 80 ug/M; and within the city the yearly arithmetic average all stations shall not exceed 60 ug/M.
    E. 
    Hydrogen sulfide at point of measurement shall not exceed the following limit: any time, 0.1 ppm.
    F. 
    Carbon monoxide at point of measurement shall not exceed the following limits: twenty-four-hour average, five ppm; eight-hour average, 15 ppm; one-hour maximum, 20 ppm; maximum at any time, 30 ppm.
    G. 
    Total oxidants at point of measurement shall not exceed the following limits: twenty-four-hour average, 0.05 ppm; one-hour average, 0.10 ppm; maximum at any time, 0.15 ppm.